personalEYES on Facebook
|
personalEYES BLOG
Visual outcomes after accommodating intraocular lens implantationMarian S. Macsai, MD, Lissa Padnick-Silver, PhD, Bruno M. Fontes, MD
PURPOSE: To evaluate and compare the visual outcomes and accommodative amplitude in cataract patients after implantation of the Crystalens intraocular lens (IOL) (Eyeonics) versus standard monofocal IOLs.
SETTING: Ten clinics in a nationwide multicenter study in the United States.
METHODS: A multicenter comparative interventional case series with masked randomized postoperative examination of 224 eyes of 112 patients was performed by a single observer. Patients were divided into 2 groups (56 patients; 112 eyes each) depending on which IOL was implanted (Crystalens or monofocal). Accommodation was measured using 1 objective (dynamic retinoscopy) and 2 subjective methods (defocus and near point of accommodation). Visual acuity measurements were performed under the same conditions with standard visual acuity charts.
RESULTS: Uncorrected monocular near vision was significantly better in the Crystalens group than in the standard monofocal group, with 101 of 112 eyes (90%) and 17 of 112 (15%), respectfully, reading J3 or better postoperatively. All 56 Crystalens patients had a binocular uncorrected near visual acuity of J3 or better compared with 16 of 56 (29%) standard monofocal patients. The mean postoperative monocular (0.85 G 0.30 [SD] versus 0.70 G 0.19, P<.01) and binocular (1.16 G 0.17 versus 1.01 G 0.14, P<.01) distance uncorrected visual acuities were also better in the Crystalens group than in the control group. All patients in the study achieved a corrected distance visual acuity of 20/20 or better. Measures of accommodation were significantly higher in Crystalens patients than in the monofocal IOL patients (dynamic retinoscopy 2.42G0.39 diopters [D] versus 0.91G0.24 D, P<.01; monocular defocus 1.74G 0.48 D versus 0.75G0.25 D, P<.01; monocular near point of accommodation 9.5G3.1 inches versus 34.7 G 9.8 inches, P<.01). Perceived accommodation (5.79 D) was significantly greater than the measured accommodation (1.96 to 2.42 D) in Crystalens patients (paired t test, P<.01).
CONCLUSIONS: The Crystalens IOL provided better uncorrected near and distance visual outcomes than standard monofocal IOLs in all analyses performed. Patients perceived a greater accommodation than measured. Understanding why this occurred could lead to valuable advances in accommodating IOL technology.
J Cataract Refract Surg 2006; 32:628–633 Q 2006 ASCRS and ESCRS
|